Yes – we offer complete engineering assistance for our Keyless Locking Device product line. As KLDs exert high compression and expansions forces, our Hub Calculator online tool can assist to ensure that components mounted with Climax products are of adequate strength for your application.

Our Hub Calculator can be accessed on any Keyless Locking Device page on our website.

Categories: Frequently Asked Questions, Keyless Locking Devices

2 Comments

  1. Andrew Nelson

    Using the hub calculator to find the minimum hub OD, why does the required OD increase with hub width? I would think the opposite to be true, as hub width increases it is stronger and better able to withstand the expansion force exerted by the device. Using a C133, 40000 psi yield, 50mm shaft and hub 25.4mm wide, the required OD is 5.009″. If hub width is increased to 38.1mm, the required hub OD is 5.232″

    • Tina Ward

      The required hub OD is more than cataloged because our Dn is based on 45,000 psi ten yield. Using 40,000 psi tensile yield material will drive the required OD up. Yes, 1” (25.4mm) is wider than .787”. To be able to use a .8 stress reduction in the formula, the hub needs to be 1.5 times “L” (.787 * 1.5 = 1.181”).